EasyManua.ls Logo

Raytech WR14 - Selection of the Proper Current Range; Connection to the Test Object

Raytech WR14
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 3.03
14
SELECTION OF THE PROPER CURRENT R ANGE
Ensure that the test current does not exceed 10% of the rated winding current. This could cause
erroneous reading due to heating in the winding.
CONNECTION TO THE TEST OBJECT
Always check the winding schematic on the nameplate and trace the current path through the windings.
You can save time if you measure the high voltage side in series with the low voltage side from the
same magnetic core. Because there are more turns on the high voltage side, you’ll reach saturation flux
in the core much faster. This helps to stabilize the measurement and saves time.
The potential leads must be connected in between the current leads. Do not clip the potential leads to
the current leads.

Table of Contents