Home
RayTek
Accessories
MI3
RayTek MI3 User Manual
5
of 1
of 1 rating
146 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
ASCII Programming
124
Rev. G
Nov/2015
MI3
Description
Char
Format
P
B
S
N
Legal Values
Factory defau
lt
Head /
B
ox
Top temperatur
e value
of output 2
H2O
float
H2O=
–
40.0
500°C
B
Top temperatur
e
value of output 3
1
H3O
float
H3O=
–
40.0
500°C
Top temperatur
e
value of output 4
2
H4O
float
H4
O=
–
40.0
500°C
Laser Control
3
HL
nHL
integer
0=off, 1=on, 2=flash,
3=external
0
H
Head serial number
HN
?nHN
integer
e.g. !nHN98123
set at production
H
Head special
HS
?nHS string
e.g. !99HSRAY
Set at
production
H
Head Firmware Revision
HV
?nHV
e.g. 1.01
Set in FW
H
Restore Head Factory
defaults
HXF
nHXF
H
Head ambient
I
?nI
float
answer !nI=
0099.9
H
Switch panel lock
J
X
L = locked
U = unlocked
unlocked
B
Relay alarm output
control
depreciated for MI3
(use
the commands KB and
KH instead of)
K
K
integer
0 = off
1 = on
2 = Target no
rm. open
3 = Target nor
m. closed
4 = Intern norm
. open
5 = Intern norm
. closed
2
H
Relay alarm output
control
KB
KB
integer
0 = off
1 = on
2 = norm. open
3 = norm. closed
2
B
Relay alarm output
control
KH
nKH
integer
0 = off
1 = target temp.
2 = head ambient
1
H
Bottom temperature
value of output 1
L1O
(L)
4
float
L1O=
–
40.0 or
L=
–
40.0
0°C
B
Bottom temperature
value of output 2
L2O
float
L2O=
–
40.0
0°C
B
Bottom temperature
value of output 3
5
L3O
float
L3O=
–
40.0
0°C
Bottom temperature
value of output 4
6
L4O
float
L4O=
–
40.0
0°C
1
for MI3MCOMMA o
nly
2
for MI3MCOMMA o
nly
3
for MI3100 heads
only
4
for MI3COMM o
nly
5
for MI3MCOMMA o
nly
6
for MI3MCOMMA o
nly
123
125
Table of Contents
Default Chapter
1
Operating Instructions
1
Table of Contents
5
Data Logging
8
Lock Mode
9
1 Safety Instructions
10
2 Description
13
Overview Comm Boxe
14
3 Technical Data
15
Comm Box
16
O Ptical C Harts
17
E Lectrical S Pecification
18
E Nvironmental S Pecification
19
Comm Box (DIN)
20
D Imensions
21
Scope of Delivery
22
Comm Box
23
4 Basics
24
Installation
26
Comm Box (DIN)
27
Comm Box (Metal)
28
Comm Box (DIN)
29
Comm Box (DIN 3TE)
30
Comm Box (DIN 4 TE)
31
Comm Box (DIN 6 TE)
32
EMI Resistance for Comm Box (DIN)
35
Power on Procedure
36
F Ieldbus
39
6 Outputs
40
A Nalog O Utputs Out1 - Out4
41
T Hermocouple O Utput Tc
42
7 Inputs
43
E Missivity ( Digital )
44
Trigger/Hold
46
L Aser S Witching
47
Control Panel
48
Head> Page
50
Box Info> Page
53
Peak Hold
54
Advanced Peak Hold
55
Advanced Valley Hold
56
9 Options
57
Avoidance of Condensation
58
I Ntrinsic S Afety
59
Installation
60
Mains Supply
61
Ex Power Supply 115MI3ACIS / 230MI3ACIS
63
10 Accessories
64
USB/RS485 Adapter
67
A Ccessories (Lt, G5 H Eads )
68
Adjustable Mounting Bracket
69
Fixed Mounting Bracket
70
Air Cooling System
71
Right Angle Mirror
75
Protective Windows
76
A Ccessories (1M, 2M H Eads )
78
Fixed Mounting Bracket
79
Adjustable Mounting Bracket
80
Isolation Kit
81
Right Angle Mirror
82
Protective Window
83
11 Maintenance
84
Cleaning the Lens
85
S Ensing H Ead E Xchange
86
Software Features
87
13 Rs485
88
14 Profibus
89
Comm Box (DIN)
91
P Rogramming
92
Input Data
93
Output Data
94
15 Modbus
97
Comm Box (DIN)
98
P Rogramming
99
Head Parameter
101
Ethernet
103
A Ddressing
104
PC Network Adapter
105
Ascii P Rogramming
106
Http S Erver
107
Profinet
109
P Rogramming
110
Parameters of the Fieldbus Communicator
111
Parameters of the Pyrometer Module
113
Input Data Structure
114
Ascii Programming
116
A Ddressing
117
D Evice I Nformation
118
Emissivity Setting and Alarm Set Points
119
Device Control
120
Command Set
121
Appendix
128
C Onformity for S Ensing H Eads
132
C Onformity for S Ensing H Eads
138
C Onformity for P Ower S Upply
142
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the RayTek MI3 and is the answer not in the manual?
Ask a question
RayTek MI3 Specifications
General
Spectral Response
8 to 14 µm
Response Time
500 ms
Display Resolution
0.1 °C
Accuracy
±1% or 1°C (2°F), whichever is greater
Emissivity
Adjustable 0.10 to 1.00