Operator manual
Compass
STD 22
110--233
STD22 Compact and STD22
19
3646/110 --233.DOC010102
Edition: Feb. 17, 2006
2.1.3 Overview of indications (digital display) during operation
Once the compass is switched on the digital display indicates as follows:
Indications Comments, Information
¡ Heating stage
Example
The temperature of the supporting liquid is
displayed during the heating stage.
Example:
h 28.8 = 28.8 °C heating stage
© Settling stage
lit up
Example
The gyro compass is settling in.
-- The course is indicated with an
illuminated dot after the last figure during
the settling stage (approx. 4 hours)
The course value is still not accurate!
¢ Course indication
Example
Once the settling process
has ended:
Course accuracy:
-- 4 hours after switching on is better than 2°
or
-- with Quick-Settling 1 hour after
switching on is better than 3°
-- Approximately 5 hours after switching on
0.2° dynamic, 0.1° static