CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.
TECHNICAL SPECIFICATIONS -CUT40(110V)
INPUT-SINGLEPHASE 60HERTZ
Standard Voltage
110V ±10% / 1 / 60Hz
REQUIRED GAS INLET PRESSURE
70 PSI @ 125-200 SCFH
( 5 Bar. @ 80±20 LITERS/MIN.)
80 to 110 PSI
(6 Bar. to 7.5 Bar.)
RECOMMEND INPUT WIRE AND FUSE SIZES
For all plasma cutting applications
Based on Ambient Temperature ≤30
o
C
AC Input
Voltage
at
50\60
Hertz
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
Type S, SO, ST, STO or extra
hard usage input cord
AWG (IEC) Sizes
Weight
Including
Torch Cable
OPERATING TEMPERATURE RANGE
-10°C to +40°C
STORAGE TEMPERATURE RANGE
-10°C to +40°C