Five equipment processing operations
Before the device operating, according to the "System operating instructions" describes, download the process
files into laser device.
5.1 Please place the work-piece on the working platform of the machine before processing.(Note:
to ensure flatness of the processed material, otherwise it will affect the processing results)
5.2 Click “on, down, left, right” button on the device control panel, Moving the laser head to the
proper location of materials to determine the origin,(press Origin” button
5.3Adjust the focus lensFigure12
5.4Click"start" button in control panel, processing start
Six Equipment Maintenance and precautions
The key to make the laser equipment normally stable operation is to do routine maintenance and
equipment maintenance. It is not only to extend the life of the machine, reduce equipment failure rates,
but also to improve product quality if the equipment maintenance is goodTo make better use of this
equipment, the following is a brief introduction about machine routine maintenance and precautions.
6.1 Ground Wire
Because of it is containing switching power supply, laser power,filter and the sensitivity of the original
deviceand these parts will have some degree of static interference during usage.To minimize static
electricity, as well as to reduce a failure due to static electricity caused, there should note the following
point before installation :
6.1.1 if the Voltage is 220V, if out of range or unstable, regulator should be installed.
6.1.2 if Power outlet is the Left 'zero' Right 'fire' standard wiring, and the ground terminal should
be reliable, grounded
If not, it should be adjusted.
6.1.3 If the customer has a reliable earth ground Or an iron bar longer than one meter to hit
underground, grounded)