18
2. Press the ENTER button to conrm selection and skip to
next parameter.
Note: At any time, you can press the ESC button to exit the Setup mode
and resume normal operation.
Setting the Criterion Level in dB (SEt LC)
Follow steps 1 and 2 when "SEt LC" appears on the LCD.
1. Use the
and buttons to adjust the criterion level between 80,
84, 85, and 90 dB.
2. Press the ENTER button to conrm selection and skip to
next parameter.
Note: At any time, you can press the ESC button to exit the Setup mode
and resume normal operation.
Setting the Threshold in dB (SEt LT)
Follow steps 1 and 2 when "SEt LT" appears on the LCD.
1. Use the
and buttons to adjust the threshold which can be set
anywhere between 70 and 90 dB.
2. Press the ENTER button to conrm selection and skip to
next parameter.
Note: At any time, you can press the ESC button to exit the Setup mode
and resume normal operation.
Setting the Exchange Rate in dB (SEt ER)
Follow steps 1 and 2 when "SEt ER" appears on the LCD.
1. Use the
and buttons to adjust the threshold which can be set
between 3, 4, 5 and 6 dB.
2. Press the ENTER button to conrm selection and skip to
next parameter.
Note: At any time, you can press the ESC button to exit the Setup mode
and resume normal operation.
continued...