22
Accessories and Replacement Parts
• R8085-PC PC Software for Noise Dosimeter
• R8085-USB USB Cable for Noise Dosimeter
• CA-52A Soft Carrying Case
• R8888 Hard Carrying Case
• R8090 Sound Level Calibrator
• R1500 Tripod
Don't see your part listed here? For a complete list of all accessories and
replacement parts visit your product page on www.reedinstruments.com.
Appendix A: USA Regulations - OSHA Regulation
Conversion Charts
OSHA Permissible Noise Exposures
Duration per day, hours
Sound level dBA,
slow response
8 90
6 92
4 95
3 97
2 100
1.5 102
1 105
0.5 110
0.25 or less 115
Source: 29 CFR 1910 Table G-16
For up-to-date information, please visit
https://www.osha.gov/dts/osta/otm/new_noise/#standards