MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
142 8540780 • 07/05/2018 • Rev.33
English
MUTING FUNCTION
The Muting function generates a temporary, automatic interruption of safety device operation in
order to permit normal transit of material through the guarded opening.
In other words, when the system recognizes the material and distinguishes between this and any
operator (in a potentially dangerous situation), it is enabled to bypass the safety device
temporarily, allowing the material to pass through the guarded opening.
MUTING OPERATORS (max number = 4)
"Concurrent" MUTING
The activation of the Muting function occurs
following interruption of the sensors S1 and S2
beam (the order does not matter) within a time
range from 2s and 5s decided by the operator (or
S3 and S4 with material that is moving in the
direction opposite).
Parameters
Timeout (sec)
Enable
Direction
Muting Close