ENELEX MK4
OPERATION/PROTECTION
THERMAL CUT-OUT
If the amplier reaches a temperature liable to cause internal electronic damage, a thermal protection sensor will shut the unit o󰀨 or disable
speaker output. The unit should be turned o󰀨 for at least 10 minutes to allow for cooling. After this period, the amplier should automatically
reset and continue to work normally. If it does not, turn the unit o󰀨 for a longer period, allowing complete cooling of the amplier before
trying again.
OPERATING TEMPERATURE
Allow adequate air circulation around the left and right-hand sides of the product, as these are the heat sinks for the power amplier and
will run hot with high listening levels. This unit is intended for use in moderate climates. Recommended ambient operating temperature 5 to
35°C.
The thermal cut-out should only occur with continuous over-driving of a di󰀩cult load. If it occurs under normal conditions, there could be
a problem with insu󰀩cient airow around the heat sinks or a fault with the loudspeakers. In this case it is advisable to contact your Rega
dealer.
DC PROTECTION
One of the design requirements of the Elex MK4 was to keep the capacitors in the signal path to a minimum to prevent unnecessary sound
degradation at this crucial line level stage. To achieve this requirement, the output of the power amplier is DC coupled. In the unlikely
event of a circuit failure causing any one of the above outputs to produce an excessive DC voltage, the DC protection will activate within
milliseconds, protecting any connected device.
SHORT CIRCUIT PROTECTION
If the speaker leads are shorted, the fold back short circuit protection will protect the output stage from excessive currents. This protection
circuit is not placed in the audio signal path and therefore does not a󰀨ect sound quality.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rega ELEX MK4 and is the answer not in the manual?

Rega ELEX MK4 Specifications

General IconGeneral
Line Input Sensitivity210 mV
Input Impedance47 kΩ
Power Output72 W per channel into 8 Ω
Inputs1 x Phono
OutputsRecord Out, Headphone Out
Input Sensitivity210 mV (Line)
Total Harmonic Distortion<0.007%
Dimensions432 x 82 x 340 mm