Table of contents
1 Safety and usage instructions............................................................................................................. 5
1.1 General safety notes....................................................................................................................... 5
1.2 Identification of notes...................................................................................................................... 5
1.3 Personnel qualifications.................................................................................................................. 5
1.4 Dangers of failure to observe the safety notes................................................................................ 5
1.5 Safety-conscious working............................................................................................................... 6
1.6 Safety instructions for the operator................................................................................................. 6
1.7 Safety notes for installation, maintenance and inspection ............................................................. 6
1.8 Unauthorised modification and changes......................................................................................... 7
1.9 Intended use................................................................................................................................... 7
1.10 Warranty........................................................................................................................................ 7
1.11 Transport and packaging............................................................................................................... 7
1.12 Environmental protection and recycling........................................................................................ 8
2 Technical data........................................................................................................................................ 9
2.1 Unit data.......................................................................................................................................... 9
2.2 Unit dimensions............................................................................................................................. 12
3 Design and function............................................................................................................................ 13
3.1 Unit description............................................................................................................................. 13
4 Operation............................................................................................................................................. 14
4.1 General notes................................................................................................................................ 14
4.2 Display on indoor unit.................................................................................................................... 14
4.3 Keys on the remote control........................................................................................................... 15
5 Installation Instructions for qualified personnel.............................................................................. 22
5.1 Important notes prior to installation............................................................................................... 22
5.2 Wall openings................................................................................................................................ 22
5.3 Installation materials..................................................................................................................... 22
5.4 Selection of installation location ................................................................................................... 23
5.5 Minimum clearances..................................................................................................................... 24
5.6 Wall bracket.................................................................................................................................. 25
5.7 Connection variants for the indoor unit......................................................................................... 26
5.8 Connection of the indoor unit when the refrigerant piping is installed under the plaster............... 26
5.9 Oil return measures....................................................................................................................... 27
6 Installation........................................................................................................................................... 27
6.1 Installation of the indoor unit......................................................................................................... 27
6.2 Connecting the refrigerant piping.................................................................................................. 28
6.3 Additional notes on connecting the refrigerant piping................................................................... 30
6.4 Leak testing................................................................................................................................... 30
6.5 Adding refrigerant.......................................................................................................................... 31
6.6 Condensate drainage connection and safe drainage.................................................................... 31
7 Electrical wiring................................................................................................................................... 33
7.1 General Information...................................................................................................................... 33
7.2 Connecting the indoor unit............................................................................................................ 33
7.3 Connecting the outdoor unit.......................................................................................................... 34
7.4 Electrical wiring diagram............................................................................................................... 34
7.5 Electrical drawings........................................................................................................................ 36
7.6 Connection of a superordinate controller provided by the customer............................................. 40
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REMKO ML Series and is the answer not in the manual?

REMKO ML Series Specifications

General IconGeneral
BrandREMKO
ModelML Series
CategoryAir Conditioner
LanguageEnglish