2 Technical data
2.1 Unit data
Series ML 265 DC ML 355 DC ML 525 DC ML 685 DC
Operating mode
Inverter wall-mounted room air conditioner combination for
cooling and heating
Nominal cooling output
1)
kW
2.6 (0.9-3.2) 3.5 (0.8-4.2) 5.3 (1.7-6.2) 7.2 (2.6-8.4)
Energy efficiency ratio SEER
1)
7.1 7.5 6.7 6.4
Electrical rated power consumption,
cooling
1)
kW 0.75 1.05 1.46 2.40
Electrical rated current consumption,
cooling
1)
A 3.25 4.74 6.35 10.55
Power consumption, annual, Q
CE
3)
kWh 128 175 290 394
Energy efficiency ratio, cooling
1)
A++ A++ A++ A++
Nominal heat capacity
2)
kW
2.6 (0.9-3.7) 2.8 (0.8-4.8) 5.3 (1.1-7.0) 5.1 (1.5-9.4)
Energy efficiency ratio SCOP
4)
4.0 4.2 4.0 4.0
Electrical rated power consumption,
heating
2)
kW 0.72 1.05 1.45 2.18
Electrical rated current consumption,
heating
2)
A 3.44 4.5 6.4 9.5
Power consumption, annual, Q
HE
3)
kWh 875 922 1365 1785
Energy efficiency ratio, heating
2)
A+ A+ A+ A+
Max. power consumption kW 2.1 2.2 2.6 3.6
Max. current consumption A 9.5 10.0 11.5 16.0
EDP no. 1635265 1635355 1635525 1635685
1)
Air inlet temp. TK 27 °C/FK 19 °C, outside temperature TK 35 °C, FK 24 °C, max. air flow volume,
5 m pipe length
2)
Air inlet temp. TK 20 °C, outside temperature TK 7 °C, FK 6 °C, max. air flow volume, 5 m pipe length
3)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
4)
The specified value is based on the average heating period
9