RL78/G13 CHAPTER 6 TIMER ARRAY UNIT
R01UH0146EJ0100 Rev.1.00 343
Sep 22, 2011
Figure 6-8. Format of Timer Mode Register mn (TMRmn) (4/4)
Address: F0190H, F0191H (TMR00) to F019EH, F019FH (TMR07) After reset: 0000H R/W
F01D0H, F01D1H (TMR10) to F01DEH, F01DFH (TMR17)
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TMRmn
(n = 2, 4, 6 )
CKS
mn1
CKS
mn0
0
CCS
mn
MAST
ERmn
STS
mn2
STS
mn1
STS
mn0
CIS
mn1
CIS
mn0
0 0
MD
mn3
MD
mn2
MD
mn1
MD
mn0
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TMRmn
(n = 1, 3)
CKS
mn1
CKS
mn0
0
CCS
mn
SPLIT
mn
STS
mn2
STS
mn1
STS
mn0
CIS
mn1
CIS
mn0
0 0
MD
mn3
MD
mn2
MD
mn1
MD
mn0
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TMRmn
(n = 0, 5, 7)
CKS
mn1
CKS
mn0
0
CCS
mn
0
STS
mn2
STS
mn1
STS
mn0
CIS
mn1
CIS
mn0
0 0
MD
mn3
MD
mn2
MD
mn1
MD
mn0
Operation mode
(Value set by the MDmn3 to MDmn1 bits
(see table above))
MD
mn0
Setting of starting counting and interrupt
0
Timer interrupt is not generated when counting is started
(timer output does not change, either).
• Interval timer mode
(0, 0, 0)
• Capture mode
(0, 1, 0)
1
Timer interrupt is generated when counting is started
(timer output also changes).
• Event counter mode
(0, 1, 1)
0
Timer interrupt is not generated when counting is started
(timer output does not change, either).
0
Start trigger is invalid during counting operation.
At that time, interrupt is not generated, either.
• One-count mode
Note 1
(1, 0, 0)
1
Start trigger is valid during counting operation
Note 2
.
At that time, interrupt is also generated.
• Capture & one-count mode
(1, 1, 0)
0
Timer interrupt is not generated when counting is started
(timer output does not change, either).
Start trigger is invalid during counting operation.
At that time interrupt is not generated, either.
Other than above Setting prohibited
Notes 1. In one-count mode, interrupt output (INTTMmn) when starting a count operation and TOmn output are
not controlled.
2. If the start trigger (TSmn = 1) is issued during operation, the counter is initialaized, an interrupt is
generated, and recounting is started.
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0 to 7)
<R>
<R>