3-4
TS20 probe system: System installation
Overtravel
Do not exceed the quoted overtravel distance for each direction, otherwise the tool tip may slip off the
stylus edge, and could cause damage to the probe.
A
B
C D
Direction
Overtravel
A 3.0mm (0.12in)
B 3.0mm (0.12in)
C 1.2mm (0.05in)
D 2.3mm (0.09in)
TS20 probe with signal conditioning module
3
(0.12)
1.6µm
(63µin)
R 0.5 MAX
(R 0.02 MAX)
18,2 (0.717)
17,9 (0.705)
19.55 (0.770)
19.45 (0.766)
Ø
Ø
1.6 (0.063)
1.5 (0.059)
Clamping
screws
‘O’ ring supplied may be tted in groove to seal probe mounting.
Recommended ‘O’ ring dimensions Ø1 × 18,1 ID (Ø0.039 × 0.71 ID)
0.5 × 45°
(0.02 × 45°)
Dimensions mm (in)