Specific measures & safety measures:
The Cbase
®
is built so that it is impossible to come in contact with live components during
normal operation without performing a conscious action.
You should not be able to touch the ventilator by hand. A complete duct system has to be
connected to the ventilation unit before operating the system. The minimal length of a duct has
to be 1,5m.
The appliance cannot be opened without proper tools.
The Cbase
®
complies with legal demands for electrical appliances. The following specific
safety measures have to be taken into account:
Make sure that the appliance is disconnected from the power grid when installing or making
changes to the ventilation system.
Use adequate tools to perform repairs or maintenance on the Cbase
®
.
Only use the appliance for its intended purpose.
Always wait 30 sec when connecting the ventilation unit to the power grid.
Attention!:
The ventilation unit must operate continuously, this means that you may never
shut down the Cbase
®
. (legal obligation under NBN D50-001 Chapter 4.2. System C)
2 • Ventilation kit
1 x Motor unit EX365CB
4 x sealing cap and/or Red Ø125> Ø80mm
2 x sealing cap Ø125
1 x Adaptor 125-150 mm (extraction)
1 x power cord (if applicable)
1 x manual