20
Physical - device and water tub
Dimensions (H x W x D):
4.57" x 10.04" x 5.91"
(116 mm x 255 mm x 150 mm)
Air outlet (complies with ISO 5356-1:2004):
22 mm
Weight (device and standard water tub):
47.1 oz (1336 g)
Weight (device and cleanable water tub):
47.1 oz (1336 g)
Housing construction:
Flame retardant engineering thermoplastic
Water capacity:
To maximum fill line 380 mL
Standard water tub - material:
Injection molded plastic, stainless steel and silicone seal
Cleanable water tub - material:
Injection molded plastic, stainless steel and silicone seal
Temperature
Maximum heater plate:
154°F (68°C)
Cut-out: 165°F (74°C)
Maximum gas temperature:
106°F ( 41°C)
Air filter
Standard:
Material: Polyester non woven fiber
Average arrestance: >75% for ~7 micron dust
Hypoallergenic:
Material: Acrylic and polypropylene fibers in a polypropylene
carrier
Efficiency: >98% for ~7-8 micron dust; >80% for ~0.5 micron
dust
Aircraft use
ResMed confirms that device meets the Federal Aviation Administration (FAA) requirements (RTCA/DO-160, section 21,
category M) for all phases of air travel.
Wireless module
Technology used:
CDMA (USA only), 3G (USA and Canada only)
2G GSM (all regions except USA and Canada)
Frequencies: CDMA (850/1900 MHz)
3G (850/900/1700/1800/1900/2100 MHz)
2G (850/900/1800/1900 MHz)
Max RF power output:
CDMA 24.5 dBm
3G 33.0 dBm
2G 33.0 dBm
FCC ID: 2ACHL-A10STACD, 2ACHL-A10STA3G
IC: 9103A-A10STA3G
The AirCurve 10 device complies with FCC Rules and Industry Canada Rules.
The AirCurve 10 device should be used at a minimum distance of 0.8" (2 cm) from the body during operation.
Additional information regarding the FCC Rules and IC compliance for this device can be found on
www.resmed.com/downloads/devices
Operating pressure range
S, ST, T, PAC, iVAPS:
3 to 30 cm H
2
O
CPAP
4 to 20 cm H
2
O
Supplemental oxygen
Maximum flow: 15 L/min (S, ST, T, PAC, CPAP), 4 L/min (iVAPS)

Table of Contents

Other manuals for ResMed AirCurve 10 ST-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ResMed AirCurve 10 ST-A and is the answer not in the manual?

ResMed AirCurve 10 ST-A Specifications

General IconGeneral
BrandResMed
ModelAirCurve 10 ST-A
CategoryMedical Equipment
LanguageEnglish

Related product manuals