While water is flowing & unit
is attempting to ignite; check
DC volts across White &
Black wires at connector C:
8 – 16 DC Volts
YES
Check connector C.
Operate unit again. IF code
65 appears:
Replace control board.
NO
Turn Power OFF then ON.
While water is flowing & unit
is attempting to ignite; check
DC volts across Red & Black
wires at connector C:
8 – 16 DC Volts
YES
Check connector C.
Operate unit again. IF code
65 appears:
Replace control board.
NO
Turn Power OFF then ON.
While water is flowing & unit
is attempting to ignite; check
DC volts across Green &
Black wires at connector C:
4 – 6 DC Volts
YES
Check connector C.
Operate unit again. IF code
65 appears:
Replace control board.
NO
Operate unit. IF 65 – Error
Code appears:
Replace water volume
control valve..