Item Selections Remarks
Duplex Tray
Horizontal (-15 to +15) step
1.32mm per step. Range is -5mm to +5mm.
If the machine settings are reset to the factory
defaults, this value does not change.
The printer will exit the energy saver state
after this setting is changed.
Vertical (-15 to +15) step
0.24mm per step. Range is -3.6mm to
+3.6mm.
If the machine settings are reset to the factory
defaults, this value does not change.
The printer will exit the energy saver state
after this setting is changed.
Fuser SC Reset
This button is for resetting an SC related with
the fusing errors.
Fuser SC Detect On/Off
If On, the engine detects SC559. If Off, the
engine does not detect "Fusing SC Reset".
Reset Transfer Unit Life
Counter
Resets the transfer unit life counter.
Trans. Belt Adjust
When you click the [Trans. Belt Adjust]
button, the transfer belt adjustment is done.
This calibrates the motor speed to match the
length of the new transfer belt.
"*" indicates the factory default value.
4. Appendix: SP Mode Tables