007 T2:HlfSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
014 ByPas:NorSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
015 ByPas:HlfSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
018 Dup:NorSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
021 Dup:HlfSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
063 T1:LowSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
065 ByPas:LowSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
066 Dup:LowSpd 0.3mm *EGB [0 to 9.0 / 0 / 0.3 mm/step]
1102 [S-to-S Reg.] Side-to-Side Registration
These SPs can be adjusted by UP mode. The setting range of SP1102 is different from
the setting range of SP1002.
001 By-pass 0.34mm *EGB
Adjusts the side-to-side registration for each
mode. This SP changes the laser main scan
start position.
[-15 to 15 / 0 / 0.34 mm /step]
002 Tray1 0.34mm *EGB
003 Tray2 0.34mm *EGB
004 Duplex 0.34mm *EGB
1105
[Temp. Adj.] Temperature Adjustment
Adjusts the fusing unit temperature.
001 Fusing Temp. *EGB [100 to 180 / 160 / 10 deg /step]
1159 [Fusing JAM SC] Fusing JAM SC Setting
001
Fusing JAM SC 0:OFF
1:ON
*EGB
Turns on or off the fusing jam SC to detect the
three consecutive paper jams at fusing unit.
[0 or 1 / 0 / 1 /step]
0: OFF, 1: ON
1900
[Print Support]
These SPs can be adjusted by UP mode.