5307 003 Rule Set(Start) -
NA: 04100010, EU: 035(4)00010,
ASIA: 105(4)00010
Specifies the start setting for the summer time mode.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [1 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
7th digit: The length of the advanced time. [0 to 9 / 1 hour /step]
8th digit: The length of the advanced time. [0 to 5 / 10 minutes /step]
For example: 3500010 (EU default)
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5307 004 Rule Set(End) -
NA: 105(4)60000, EU: 105(4)00000,
ASIA: 03100000
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5401 [Access Control]
5401 104 Authentication Time
*CTL
[0 to 255 / 0 / 1 sec/step]
0: 60 seconds
Specifies the authentication time-out interval.