Technical Bulletin PAGE: 5/5
Model: AL-P1 Date:21-Dec-09 No.: RG179015
IV. Set the following SP modes to the values shown.
SP Mode: Set to this value:
SP 2201-01 (Development Bias): 560(default)
SP 2201-02 (Development Bias for ID sensor pattern): 400(default)
Note: For high-CV users (APV: 30K or more), set this SP to a value of 460.
SP 2001-01 (Charge Roller Bias): 1500(default)