Technical Bulletin PAGE: 2/2
Reissued: 17-Oct-16
Model: GR-C1
Date: 27-Mar-12
No.: RD117014g
Version
Modified Points or Symptom Corrected
05.00.00
Symptom corrected:
The machine may print out an incoming FAX without forwarding it, even though the
SUB code has been set and the machine is being used as a forwarding station.
Other changes:
The following bit switch was added.
Note: This allows the user to instruct the machine what to do when the forwarding of
an incoming FAX fails/succeeds.
USER 45 BIT3
0: Follow Reception File Settings (default) regardless of forwarding results
1: Follow Reception File Settings if forwarding fails, do not print if forwarding is
successful
04.00.00
Symptom corrected:
Multiple notification emails are sent out when the Results Notification feature is used.
03.00.00
Other changes:
Minor bug corrections were applied.
02.00.00
1st Mass production