Technical Bulletin PAGE: 7/9
Reissued: 20-Mar-15
Model: GR-C1
Date: 14-Jan-15
No.: RD117051b
Cause 2: Symptom occurring with time
If the sponge peels off from the molded part of the housing, cut off the peeling part of
the sponge.
Note: Cut the sponge with attention to the following measurements. Because if you
overcut the sponge, a hole in the molded part which is sealed by the sponge may
become exposed. At a result of this, toner spill may occur.
Cut the sponge OR Replace the toner housing.
P/N
Description
D1173301
HOUSING:TONER SUPPLY:ASS'Y

Table of Contents