1.SC Codes
239
Error Name/Error Condition/Major Cause/Solution
The spine fold HP sensor (right) did not go ON during operation of the right
fold plate, even after the spine fold motor (right) was operating for 3225 ms (or
enough time elapsed for the plate to travel 56.25mm).
When the spine fold plate moved from the open to closed position, the spine
fold HP sensor (right) was already OFF.
Spine fold motor (R) connector loose, broken, defective
Motor defective
Spine fold HP sensor (R) connector loose, broken, defective
Sensor defective
Reconnect the connector.
Replace the spine fold motor (R).
Replace the Spine fold HP sensor (R).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Spine fold HP sensor (R) lag error
The spine fold (right) HP sensor did not go OFF when the spine fold plate
closed, even while the spine fold motor (right) was operating for 500 ms.
When the spine fold plate moved from the closed to open position, the spine
fold HP sensor (right) was already ON.
Spine fold motor (R) connector loose, broken, defective
Motor defective
Spine fold HP sensor (R) connector loose, broken, defective.
Reconnect the connector.
Replace the spine fold motor (R).
Replace the spine fold HP sensor (R).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Right spine fold plate close error
The spine fold press sensor (right) did not go ON when the right fold plate was
closing, even after the spine fold motor (right) was operating for 3225 ms (or
enough time elapsed for the plate to travel 56.25mm).