EasyManua.ls Logo

Riden RD6012 - Page 36

Riden RD6012
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Save Mult.
Appearance
ON Save the multiplier position for future value adjustments.
OFF Multiplier position will return to the lowest position for every change.
Multiplier Position refers to the digit highlighted when changing a setting value.
{ToDo: Add example image}
Note:
Upon each power-up of the RD60xx the multiplier will be reset to the lowest
position regardless of this setting.
SaveGraphSett.
Appearance
ON Save the last used Graph Display Settings as default for next use.
OFF Graph Mode will display everything using the default settings each power-up.
Notes:
Saves graph settings for Vertical Scale and Y-offsets.
See ‘Graph Display - Detailed Explanation for a detailed explanation of the
Graphing Mode.
Screensaver
Display
Never Do NOT enable Screensaver after a set time.
Settable Range: 00h 01m - 59h 59m.
IF NO user input:
Screen brightness will decrease to the ‘ScrsaverBright’ value after set time.
Notes:
Timer will reset with each key press.
Will NOT activate if RD60xx Output ON.
(Unless ‘ScrsaverActive enabled)
When screensaver is active:
Any key press, except “ON/OFF”, will return ther display to the ‘Backlight
setting.
A OVP, OCP, OPP, OTP, Battery detect, or Battery disconnect event will
return ther display to the ‘Backlight setting.