TECHNICAL DATA
(1) Reference conditions: Ambient temperature 20
°
C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 8)(A)p.8, with zero pressure in the combustion chambre an maximum burner output.
(2) Sound pressure measured in manufacturerÕs combustion laboratory, with burner operating on test boiler and at maximum rated output.
ACCESSORIES
(optional):
¥
KIT FOR LPG OPERATION
: the kit allows the 30 - 40 BLU burners to operate on LPG.
¥
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valve, pressure governor and Þlter):
see page 18.
MODEL RS 30 BLU RS 40 BLU
TYPE 831 T1 827 T1
OUTPUT
(1)
2nd stage
kW
210 - 350
181 - 300
325 - 465
280 - 400
Mcal/h
min. 1st stage
kW
130
112
175
150
Mcal/h
FUEL NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20 G25 G20 G25
- Net caloriÞc value
kWh/Nm
3
Mcal/Nm
3
10
8,6
8,6
7,4
10
8,6
8,6
7,4
- Absolute density
kg/Nm
3
0,71 0,78 0,71 0,78
- Max delivery
Nm
3
/h
35 40 46 54
- Pressure at maximunm delivery
(2)
mbar 13,3 19,7 13,8 20,4
OPERATION
- Intermittent (min. 1 stop in 24 hours)
- Two - stage (high and low ßame) and single-stage (all - nothing)
STANDARD APPLICATIONS Boilers: water, steam, diathermic oil
AMBIENT TEMPERATURE
°
C 0 - 40
COMBUSTION AIR TEMPERATURE
°
C max 60
ELECTRICAL SUPPLY V ~ 50 Hz 230 V (+/- 10%)
ELECTRIC MOTOR
W
V
A
420
220 - 240
2,9
420
220 - 240
2,9
MOTOR CAPACITOR
m
F / V 12,5/450
IGNITION TRANSFORMER
V1 - V2
I1 - I2
230 V - 1x 8 kV
1 A - 20 mA
ELECTRICAL POWER CONSUMPTION W max 600
ELECTRICAL PROTECTION IP 44
ELECTROMAGNETIC COMPATIBILITY 90/396 - 89/336 - 73/23 - 92/42
NOISE LEVELS
(3)
dBA 70 70
APPROVAL CE 0063AR4682
APPROVAL BUWAL Nr 196020
BURNER RS 30 BLU RS 40 BLU
OUTPUT kW 130
¸
350 175
¸
465
CODE 3010148 3010149
COUNTRY CATEGORY
IT - AT - GR - DK - FI - SE II
2H3B / P
ES - GB - IE - PT II
2H3P
NL II
2L3B / P
FR II
2Er3P
DE II
2ELL3B /P
BE I
2E(R)B,
I
3P
LU II
2E3B /P
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.