RIGOL  Chapter 1 Quick Start 
1-14  DG1000Z User’s Guide 
Power On and Inspection 
 
To Connect to Power 
 
Please connect the generator to AC power supply using the power cord supplied in 
the accessories (as shown in the figure below). The AC power supply specification of 
this generator is 100-240V, 45-440Hz. The maximum input power of the instrument 
cannot exceed 30W. When the signal generator is connected to AC power supply via 
this connector, the instrument  adjusts  itself to select the correct voltage range 
automatically and users do not need to select the voltage range manually.  
 
 
Figure 1-3 Connect to Power 
 
 
To avoid electric shock, make sure that the instrument is correctly 
grounded.  
 
Power-on 
 
After the power supply is correctly connected, press the power key 
 at the front 
panel to turn on the generator. During the start-up, the instrument executes 
initialization and self-test. After that, the default interface is displayed. If the 
instrument does not start normally, please refer to the introduction in 
“Troubleshooting”.  
 
To Set the System Language 
 
DG1000Z series supports multiple language menus. You can press Utility  
Language to select the desired system language.