Chapter 2 Front Panel Operations  RIGOL 
DG1000Z User’s Guide  2-59 
Sweep Type 
 
DG1000Z provides Linear, Log and Step sweep types and the default is Linear 
sweep.  
 
Linear Sweep 
 
In linear sweep type, the output frequency of the instrument varies linearly in the 
way of “several Hertz per second”. The variation is controlled by “Start Frequency”, 
“Stop Frequency” and “Sweep Time”.  
 
When Sweep is enabled, press Type to select “Linear”. A straight line is displayed 
on the waveform on the screen, indicating that the output frequency varies linearly.  
 
Figure 2-7 Linear Sweep 
 
 
Log Sweep 
 
In Log Sweep type, the output frequency of the instrument varies in a logarithmic 
fashion, that is, the output frequency changes in the way of “octave per second” or 
“decade per second”.  The variation is controlled by “Start Frequency”,  “Stop 
Frequency” and “Sweep Time”. 
 
When Log Sweep is enabled, users could set the following parameter:  
Start Frequency (
), Stop Frequency (
) and Sweep Time (
). 
The function prototype of Log Sweep: 
 
 
is the instantaneous frequency of the current output. 
 and 
 could be 
expressed as shown below by the above-mentioned parameters: 
sweepstartstop
TFF
P
/)/lg(
10=
 
 
Wherein, 
 is the time from the start of the sweep and its range is from 0 to 
. 
 
When Sweep is enabled, press Type to select “Log”. An exponential function curve 
is displayed on the waveform on the screen, indicating that the output frequency 
changes in a logarithmic mode.