RIGOL
DG1000 Service Guide
III
authorized personnel before further operations. Any maintenance, adjustment or
replacement especially to circuits or accessories must be performed by RIGOL
authorized personnel.
Provide Adequate Ventilation.
Inadequate ventilation may cause an increase of temperature in the instrument, which
would cause damage to the instrument. So please keep the instrument well ventilated
and inspect the intake and fan regularly.
Do Not Operate in Wet Conditions.
To avoid short circuiting to the interior of the instrument or an electric shock, never
operate the instrument in a humid environment.
Do Not Operate in an Explosive Atmosphere.
To avoid personal injuries or damage to the instrument, never operate the instrument
in an explosive atmosphere.
Keep Instrument Surfaces Clean and Dry.
To avoid dust or moisture from affecting the performance of the instrument, keep the
surfaces of the instrument clean and dry.
Prevent Electrostatic Impact.
Operate the instrument in an electrostatic discharge protective environment to avoid
damage induced by static discharges. Always ground both the internal and external
conductors of cables to release static before making connections.
Use the Battery Properly.
Do not expose the battery (if available) to high temperature or fire. Improper change
of a battery (lithium battery) may cause an explosion. Use the RIGOL specified
battery only.
Handle with Caution.
Please handle with care during transportation to avoid damage to keys, knobs,
interfaces and other parts on the panels.

Other manuals for Rigol DG1022

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DG1022 and is the answer not in the manual?

Rigol DG1022 Specifications

General IconGeneral
ModelDG1022
TypeFunction/Arbitrary Waveform Generator
Channels2
Maximum Frequency20 MHz
Frequency Range1 μHz to 20 MHz
Sample Rate100 MSa/s
Vertical Resolution14 bits
Waveform TypesSine, Square, Ramp, Pulse, Noise, Arbitrary
Output Impedance50 Ω
Modulation TypesAM, FM, PM, FSK, PWM
Sweep ModesLinear, Logarithmic
Frequency Accuracy±20 ppm
Frequency Resolution1 μHz
Display3.5 inch TFT LCD
Waveform Length8 kpts
Arbitrary Waveform Length8 kpts
Amplitude Accuracy±(1% of setting + 1 mVpp)
InterfacesUSB Device, USB Host
Power Supply100-240 V AC