RIGOL
DG1000 Service Guide
II
Safety Requirement
General Safety Summary
Please review the following safety precautions carefully before putting the instrument
into operation so as to avoid any personal injury or damage to the instrument and any
product connected to it. To prevent potential hazards, please follow the instructions
specified in this manual to use the instrument properly.
Use Proper Power Cord.
Only the exclusive power cord designed for the instrument and authorized for use
within the local country could be used.
Ground the Instrument.
The instrument is grounded through the Protective Earth lead of the power cord. To
avoid electric shock, connect the earth terminal of the power cord to the Protective
Earth terminal before connecting any input or output terminals.
Connect the Probe Correctly.
If a probe is used, do not connect the ground lead to high voltage since it has isobaric
electric potential as the ground.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe all ratings and markers on the instrument and
check your manual for more information about ratings before connecting the
instrument.
Use Proper Overvoltage Protection.
Ensure that no overvoltage (such as that caused by a bolt of lightning) can reach the
product. Otherwise, the operator might be exposed to the danger of an electric shock.
Do Not Operate Without Covers.
Do not operate the instrument with covers or panels removed.
Do Not Insert Anything Into the Air Outlet.
Do not insert anything into the air outlet to avoid damage to the instrument.
Use Proper Fuse.
Please use the specified fuses.
Avoid Circuit or Wire Exposure.
Do not touch exposed junctions and components when the unit is powered on.
Do Not Operate With Suspected Failures.
If you suspect damage occurs to the instrument, have it inspected by RIGOL

Other manuals for Rigol DG1022

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DG1022 and is the answer not in the manual?

Rigol DG1022 Specifications

General IconGeneral
ModelDG1022
TypeFunction/Arbitrary Waveform Generator
Channels2
Maximum Frequency20 MHz
Frequency Range1 μHz to 20 MHz
Sample Rate100 MSa/s
Vertical Resolution14 bits
Waveform TypesSine, Square, Ramp, Pulse, Noise, Arbitrary
Output Impedance50 Ω
Modulation TypesAM, FM, PM, FSK, PWM
Sweep ModesLinear, Logarithmic
Frequency Accuracy±20 ppm
Frequency Resolution1 μHz
Display3.5 inch TFT LCD
Waveform Length8 kpts
Arbitrary Waveform Length8 kpts
Amplitude Accuracy±(1% of setting + 1 mVpp)
InterfacesUSB Device, USB Host
Power Supply100-240 V AC