1. :function?
Command Format:
:function?
Function:
The command queries the current measuring function. If in Dual Display mode,
queries the function of main display.
Return Format:
The query returns the current DM3058 measuring function‘s shortening. The
possible return values are: DCV, ACV, DCI, ACI, RESISTANCE, CAPACITANCE,
CONTINUITY, FRESISTANCE, DIODE, FREQUENCY, PERIOD.
2. :function:voltage:DC
Command Format:
:function:voltage:DC
Function:
The command enables DC voltage measuring function.
Explanations:
In ―:function?‖, this function is corresponding to the return value ―DCV‖.
3. :function:voltage:AC
Command Format:
:function:voltage:AC
Function:
The command enables AC voltage measuring function.
Explanation:
In ―:function?‖, this function is corresponding to the return value ―ACV‖.