Command Systems RIGOL
Programming Guide for DS1000B Series
2-37
3. :TRIGger:VIDEO:STANdard
Command Format:
:TRIGger:VIDEO:STANdard {NTSC|PALSecam}
:TRIGger:VIDEO:STANdard?
Function:
The command sets the video standard as NTSC or PAL/SECAM.
Returned Format:
The query returns NTSC or PAL/SECAM.
Example:
:TRIG:VIDEO:STAN PALS Set the video standard as PAL/SECAM.
:TRIG:VIDEO:STAN? Return PAL/SECAM.
4. :TRIGger:VIDEO:LINE
Command Format:
:TRIGger:VIDEO:LINE <value>
:TRIGger:VIDEO:LINE?
Function:
The command sets the number of sync specified line. In NTSC standard, the
<value> range is 1~525; in PAL standard, the <value> range is 1~625.
Returned Format:
The query returns the number of specified line.
Example:
:TRIG:VIDEO:LINE 25 Set the number of sync specified line as 25.
:TRIG:VIDEO:LINE? Return 25.