Infinity REU-V1616W / REU-V1620W / REU-V2018W / REU-V2020W- 25 - Issue 2 - 21/03/06 ©Rinnai
15. Component Circuit Value Table
CN Wire Colour
Surge Protection B-Br AC207~264V
R(CN2-NO.4)-B
±DC11~13V
(Only When Operating)
Operate Electricity
R(CN4-NO.5)-Bk DC11~13V Control Electricity
Below DC1V (Limiter On)
DC4~6V (Limiter Off)
Below DC1V (Limiter On)
DC4~6V (Limiter Off)
Remote Control D (TERMINAL) DC11~13V
R-Bk DC11~13V
Y-Bk
GND DC4~7V (Pulse 20~320Hz)
R-Bk DC15~46V
Y-Bk DC11~13V
W-Bk
GND DC5~10V (33~400Hz)
Flame Rod B
5 Y-FLAME ROD Over DC1µA Flame Condition
Modulating Valve B
6 P-P
DC2~15V
65~85:
B
3
B4
Igniter C1 Gy-Gy AC90~110V
Main Solenoid Valve E
1 P-Bk
DC80~100V
1.7~2.1k:
Solenoid Valve 1
(Small)
E
2 B-Bk
DC80~100V
1.7~2.1k:
Solenoid Valve 2
(Large)
E
3 Y-Bk
DC80~100V
1.7~2.1k:
F R-R
AC90~110V
11~13k:
F
1 B-Br
31~36k:
Valve Heater
F
5
Y-Y
1k:
Pipe Heater
F
6 Y-Y
125k:a156k:
Pipe Heater Only
Gas
Type
Current On High On Ignition
Prop
Nat
660 ± 66mA
585 ± 59mA
297Hz / 4455rpm
279Hz / 4185rpm
180Hz / 2700rpm
180Hz / 2700rpm
Gas
Type
Current On High On Ignition
Prop
Nat
845 ± 85mA
770 ± 77mA
308Hz / 4620rpm
290Hz / 4350rpm
195Hz / 2925rpm
195Hz / 2925rpm
Gas Type High Low
Propane
Natural
0.81kPa
0.88kPa
0.18kPa
0.18kPa
2.75kPa
1.13kPa
4
Primary
Gas Secondary Pressure Secondary
10
Fan Current
REU-V1616W
10
Fan Current
REU-V2020W
REU-V2018W
10
2W-W
15° C··· 11.4 ~14.0k:
30° C··· 6.4 ~ 7.8k:
5° C··· 3.6 ~ 4.5k:
60° C··· 2.2 ~ 2.7k:
100° C··· 0.6 ~ 0.8k:
7
Transformer1
Thermal Fuse
Outgoing Thermistor
3
Combustion Fan A
18
Water Flow Sensor B
2
Full Close Position
Measurement Point
R-R
R-Bk
Below 1:
B
1
Table reference Component Normal Value
On 2.4L/min (33Hz)
Over 1980 PULSE/min
Off 1.7L/min (23Hz)
Below 1380 PULSE/min
A Note
Water Flow
Control Device
G
1
Bk-Br
Bk-Y Full Open Position