EasyManuals Logo

Rinnai REU-VRM3237WC Service Manual

Rinnai REU-VRM3237WC
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Infinity REU-VR3237WG /HD250e REU-VRM3237WC - 29 - Issue 1 - 19/05/09 ©Rinnai
To return to normal operation.
Press the ON/OFF button again while holding the Water Temperature “UP” (Hotter) button.
This feature will automatically shut down after 3 minutes.
Error History
To Display Error Memory (History)
(This feature will show the last 10 faults in sequence)
1. Turn off at the ON/OFF button. (This can be done during
operation)
2. Press the ON/OFF button while holding the Water Temperature
"UP" (Hotter) button.
The Sequence will be shown in the Water Temperature display.
Error Code will be shown in the Clock display. (See service
Manual for error codes).
Where there are less than a total of 9 errors, "FFF" or " - - " will
be displayed in the Clock display.

Other manuals for Rinnai REU-VRM3237WC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai REU-VRM3237WC and is the answer not in the manual?

Rinnai REU-VRM3237WC Specifications

General IconGeneral
BrandRinnai
ModelREU-VRM3237WC
CategoryWater Heater
LanguageEnglish

Related product manuals