Communications Manual Rev 3.10 Software Versions 3.xx
Page 12
003R-618-310
3.3. Reading Gross Weight as Literal Value
Type the following (without the “” quotes) and then press Send (which appends
<CR><LF>):
20050026:
The indicator will response with a message like:
81050026:^^10.00^kg^G (along with a trailing <CR><LF>)
3.4. Read Gross Weight as Final Value
Type the following and then press Send:
20110026:
The indicator will response with a message like:
81110026:000003E8
Where the value after the “:” is the hexadecimal value of the gross weight
without any decimal places or units. In decimal, this value is 1000. For
conversion between decimal and hexadecimal, refer to Table 7: Decimal,
Binary and Hexadecimal Conversion page 42.
3.5. Setting Values
For example, change Set Point Target 1 (overweight) to 500 kg in final form for an
indicator with units of kg.
Type the following and then press Send:
20120171:1F4 (1F4 in hexadecimal = 500 decimal)
The indicator will respond with a message like:
81120171:0000
Where the “0000” value after the “:” indicates no errors.
3.6. Remote Key Press
For example, remotely press the TARE key on an indicator.
Type the following and then press Send:
20120008:8003
The indicator will respond with a message like:
81120008:0000
Note: For the ZERO key type “20120008:8002”.
3.7. RS-232 Ring Network Enhancement
From K302 software revision V3.82+, the instruments can be installed in a Ring
Network. The central computer’s software is required to send additional framing
characters, ‘Echo-On’ (=<DC2> =ASCII 12
H
) and ‘Echo-Off(=<DC4> =ASCII 14
H
)
around each command.

Table of Contents

Other manuals for Rinstrum R320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum R320 and is the answer not in the manual?

Rinstrum R320 Specifications

General IconGeneral
CategoryAccessories
Excitation Voltage5 VDC
TypeIndicator
Display20 mm high
Power12-24 V DC
Operating Temperature-10°C to +50°C
Load Cell Connection4-wire
Communication PortsRS-232, RS-485