10.3. Examples of Operation
The following data loaded :
20120146:D020617420C0206F6E20BF0D0A
Would produce the printout below:
525 kg N at 11:04 on 03.02.2005<CR><LF>
To use the streaming tokens, the streaming register is first set up as described
above.
Streaming to print the REG_SYSTEM_ERROR, REG_ABSOLUTE_MVV, and
REG_ADC_SAMPLE_NUMBER registers:
Write Stream Register 1
20120042:03
Write Stream Register 2
20120043:04
Write Stream Register 3
20120044:01
The “Streaming Register Raw” print token when loaded :
20120146:E9
Would produce the printout below on a short press of the print button, auto, single
print, or auto print options:
000000000000138700024AED
<CR><LF>
The “Streaming Register Literal” print token when loaded :
20120146:E8
Would produce the printout below on a short press of the print button, auto, single
print, or auto print options:
E0000,0.4999,148113
<CR><LF>

Table of Contents

Other manuals for Rinstrum R320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum R320 and is the answer not in the manual?

Rinstrum R320 Specifications

General IconGeneral
BrandRinstrum
ModelR320
CategoryAccessories
LanguageEnglish

Related product manuals