Appendix E – System Testing and Maintenance
The LightSYS2 should be tested once a week. Also, the system should be checked by
a qualified engineer at least every 3 years. Your weekly test should include
:
System setting System unsetting Creating an alarm
Testing the zones in the system through a Walk Test, allowing you to open and
then close each protected door and window while listening for the keypad to beep
confirming its operation
To perform a Walk Test:
1. Make sure the system is unset.
2. Press and enter your code followed by .
3. Using the arrow keys, scroll to the option Maintenance and press
.
4. Select Walk Test and press .
5. Select Full Walk test and press
.
6. A beep is heard and the following display appears:
MAKE WALK TEST
AND HIT ANY KEY
Walk throughout the protected area and make sure you test every zone in the
system. You have 60 minutes to perform the test.
7. When done, press any key. A list of the tripped zones during the walk test
appears. Use the arrow keypad's keys to scroll through the list of the zones
logged during the test
8. Press
to confirm and exit the walk test mode.