3.1.2.2 Display End Value (dSP.E)
This screen allows the user to set the Display End value which will correspond to the
Input End value.
The End value can be set from -9999 to -10 or +10 to +9999 counts.
Initially,‘dSP.E’ message is displayed on screen following which user can start editing
Display End value by pressing the “ ” key.
Instead on pressing the “ ” key will confirm the present value and advance to
Display Start value selection (section 3.1.2.3).
After entering the edit mode, by pressing the “ ” key
user can turn the ‘-’ symbol On or Off. If ‘-’ symbol is On
then Display End value will be set as negative else it will
be positive.
Pressing the “ ” key once will set the ‘-’ symbol.
Next, on pressing “ ” key editing of Decimal point will
start. With each press of the same key, the Decimal point
will shift towards right by one digit.
Pressing the “ ” key will set the decimal point position
and advance to digit editing.
By pressing the “ ” key user can scroll the value from 0 to 9.
Pressing the “ ” key will set the first digit and advance the operation to next digit.
Similarly, user can edit the remaining three digits.
After all four digits have been set, pressing the “ ” key will advance to the Display
End value confirmation mode.
Pressing the “ ” key will re-enter into the End value edit mode.
Pressing the “ ” key will confirm the set value and advance to Display Start value
selection (section 3.1.2.3).
NOTE: The decimal point position can only be set in the Display End value screen
and the same will reflect in the measurement screen.
9