Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
221
6.3 HA Series
This address can be specified as system data area.
<Communication identifier list>
Device Bit Address Word Address
32
bits
Notes
Communication identifier 0000.00-00E8.1F 0000-00E8
*1
*2
*3
*1 There are cases for which writing is not available depending on the device address. Check the
identifying attributes of the external device’s manual before use.
*2 When bit is written, the indicator reads the corresponding word address of external device, assign
a bit to the read word address, and return to the external device. There are cases when correct data
cannot be written if the word address is written using a ladder program, while the indicator reads
data of the external device and sends it back.
*3 32-bit device
Address Identifier Description
00 M1 Input 1 measured value (PV1)
01 M0 Input 2 measured value (PV2)
02 M2 Feedback resistance input monitor
03 M3 Current transformer 1 (CT1) input value monitor
04 M4 Current transformer 2 (CT2) input value monitor
05 MS Input 1 setting-value(SV1) monitor
06 MT Input 2 setting-value(SV1) monitor
07 S2 Remote setting (RS) input value monitor
08 KH Cascade monitor
09 B1 Burnout state monitor of input 1
0A B0 Burnout state monitor of input 2
0B B2 Burnout state monitor of feedback resistance input
0C AA Event 1 state monitor
0D AB Event 2 state monitor
0E AC Event 3 state monitor
0F AD Event 4 state monitor
10 AE Heater break alarm 1 (HBA1) state
11 AF Heater break alarm 2 (HBA1) state
12 O1 Manipulated output value (MV1) of input 1
13 O0 Manipulated output value (MV2) of input 2
14 ER Error code
15 L1 Event input(DI) state
16 L0 Operation mode state
17 TR Memory area soak time monitor
18 G1 PID/AT transfer of input 1
19 G0 PID/AT transfer of input 2
1A J1 Auto/Manual transfer of input 1
1B J0 Auto/Manual transfer of input 2
1C C1 Remote/Local transfer
1D SR RUN/STOP transfer
1E ZA Memory area transfer
1F A1 Event 1 set value
20 A2 Event 2 set value
21 A3 Event 3 set value
22 A5 Control loop break alarm 1 (LBA1) time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT CB100 Series and is the answer not in the manual?

RKC INSTRUMENT CB100 Series Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelCB100 Series
CategoryTemperature Controller
LanguageEnglish

Related product manuals