15 Alarms Eagle Instruction Manual
STEL alarm (toxics only)
If a toxic gas channel’s average gas reading for the past 15 minutes
exceeds the STEL alarm setting:
STEL displays in the alarm field for that channel.
The channel’s display line flashes.
The buzzer sounds a pulsed tone.
The alarm lights flash.
TWA alarm (toxics only)
If a toxic gas channel’s average gas reading for the past 8 hours
exceeds the TWA alarm setting:
TWA displays in the alarm field for that channel.
The channel’s display line flashes.
The buzzer sounds a pulsed tone.
The alarm lights flash.
Over range alarm
If a channel’s gas reading exceeds that channel’s full-scale setting:
OVER displays in the alarm field for that channel.
The channel’s display line flashes.
The buzzer sounds a pulsed tone.
The alarm lights flash.
CH
4
OY
C
O
H
2
S
X
2
0.9
0
0
0.5
L
V
P
P
P
P
M
M
E
O
L
L
%
%
S
T
E
1
L
CH
4
OY
C
O
H
2
S
X
2
0.9
0
0
0.0
L
V
P
P
P
P
M
M
E
O
L
L
%
%
T
WA
1
CH
4
OY
C
O
H
2
S
X
4
0.0
0
0
0.0
L
V
P
P
P
P
M
M
E
O
L
L
%
%O
V
ER

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKI Instruments Eagle Series and is the answer not in the manual?

RKI Instruments Eagle Series Specifications

General IconGeneral
BrandRKI Instruments
ModelEagle Series
CategorySecurity Sensors
LanguageEnglish

Related product manuals