Portable Gas Leak Detector
SP-220 Series
TYPE F
Operating Manual
Part Number: 71-0421
Revision: P1
Released: 10/20/17

Table of Contents

Questions and Answers

  • G
    Gabriel SmithJul 31, 2025
    What to do if RKI Instruments SP-220 TYPE F display a low battery voltage alarm (FAIL BATTERY)?
    • J
      josebenjaminAug 1, 2025
      If your RKI Instruments Security Sensors show a low battery voltage alarm, it means the battery level is low. Turn off the power and replace the batteries with new ones in a safe area.
  • W
    Willie JordanAug 4, 2025
    How to fix RKI Instruments SP-220 TYPE F when the power cannot be turned on?
    • A
      Ashley AndersonAug 4, 2025
      If your RKI Instruments Security Sensors won't turn on, here are a few things to check: * If the battery level is too low, replace both batteries with new ones. * Ensure you keep the POWER button pressed until you hear a blip. * Verify the batteries are correctly installed.
  • M
    Maria JacksonAug 8, 2025
    What to do if RKI Instruments Security Sensors display a low flow rate alarm (FAIL LOW FLOW)?
    • T
      Thomas BentonAug 8, 2025
      If your RKI Instruments Security Sensors show a low flow rate alarm, it could be due to several reasons: * Check the taper nozzle for any damage or signs of drawn water or oil. * Inspect the taper nozzle for connection issues, clogging, or torsion. * If the detector was powered on at a low temperature or hasn't been used for a while, cycle the power a few times to see if the pump starts. If it doesn't, contact RKI to replace the pump. * If the pump has deteriorated, contact RKI to replace it.
  • J
    josephyoungAug 13, 2025
    What does 'FAIL SENSOR' mean on RKI Instruments SP-220 TYPE F Security Sensors and how to fix it?
    • M
      monica28Aug 13, 2025
      If your RKI Instruments Security Sensors display 'FAIL SENSOR', it indicates a sensor failure. Remove the batteries in fresh air, reinstall them, and turn the power on. Restart the detector a few times. If the problem persists, contact RKI to replace the sensor.
  • J
    Jeffery TrujilloAug 17, 2025
    Why RKI Instruments SP-220 TYPE F showing 'FAIL AIR CAL' and how to resolve it?
    • J
      Jeremy DuarteAug 17, 2025
      If your RKI Instruments Security Sensors show 'FAIL AIR CAL', it means fresh air isn't being supplied around the detector. Make sure to supply fresh air and then perform the air calibration in the measured atmosphere.
  • P
    patrickmendezAug 22, 2025
    What does 'FAIL CLOCK' mean on RKI Instruments SP-220 TYPE F Security Sensors and how can I fix it?
    • J
      John OlsonAug 22, 2025
      If your RKI Instruments Security Sensors display 'FAIL CLOCK', it indicates an abnormality with the internal clock. Try setting the date and time. If the issue persists, the built-in clock may be malfunctioning, and you should contact RKI for repair.
  • K
    Kimberly MontesAug 26, 2025
    What does 'FAIL SYSTEM' mean on RKI Instruments SP-220 TYPE F?
    • R
      Rebecca KingAug 26, 2025
      If your RKI Instruments Security Sensors display 'FAIL SYSTEM', it indicates a circuit abnormality. Contact RKI for repair.

Summary

Outline of the Product

Important Notices on Safety

2-1. Danger cases

Highlights critical safety hazards and severe consequences of improper handling.

2-2. Warning cases

Outlines significant risks and precautions to prevent serious harm or damage.

2-3. Precautions

Provides detailed cautions on environmental factors, usage, and maintenance.

How to Use

4-5. Basic operating procedures

Illustrates fundamental operational sequences using button combinations.

4-6. How to detect

Provides guidance on the proper method for detecting gases using the unit.

4-8. Performing air calibration

Step-by-step guide for executing fresh air calibration.

User Mode

Alarm Function

7-1. Gas alarm activation

Describes the conditions under which a gas alarm is triggered and its indications.

7-2. Fault alarm activation

Explains fault alarms resulting from detected abnormalities and their specific error messages.

Maintenance

Calibration Mode

9-1. Fresh Air Adjustment

Step-by-step guide for performing a fresh air calibration procedure.

9-2. Preparing for a Span Adjustment (Gas Bag)

Instructions for setting up calibration using a gas bag and tubing clamp.

9-3. Preparing for a Span Adjustment (Demand Flow Regulator)

Instructions for preparing calibration with a demand flow regulator kit.

9-4. Automatic Span Adjustment

Guides on performing an automatic span calibration for the detector.

9-5. Manual Span Adjustment

Detailed steps for manually calibrating the detector's span.

Troubleshooting

The power cannot be turned on.

Troubleshooting steps for when the detector fails to power on.

System abnormalities FAIL SYSTEM

Guides on diagnosing and resolving system failure alerts.

Sensor abnormalities FAIL SENSOR

Provides solutions for sensor-related malfunctions and error messages.

A low battery voltage alarm is displayed. FAIL BATTERY

Troubleshooting for low battery warnings and battery replacement.

A low flow rate alarm is displayed. FAIL LOW FLOW

Diagnoses and solutions for low flow rate alarm indications.

RKI Instruments SP-220 TYPE F Specifications

General IconGeneral
BrandRKI Instruments
ModelSP-220 TYPE F
CategorySecurity Sensors
LanguageEnglish