EasyManuals Logo

RKI Instruments SP-220 TYPE F User Manual

RKI Instruments SP-220 TYPE F
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
- 37 -
7
7. Alarm Function
7-1. Gas alarm activation
When the concentration of detected gas reaches or exceeds the alarm setpoint values, a "gas alarm" is
triggered in the detector. The alarm lamp blinks, the buzzer sounds, and the bar meter display indicates an
alarm condition. (Auto-reset operation)
Blinking alarm lamp and buzzer sound operation for gas alarms have different intervals depending on the
detected concentration.
7-2. Fault alarm activation
"Fault alarm" is triggered using a buzzer sound and blinking alarm lamp when an abnormality is detected in
the detector. (Self-latching)
When an alarm is triggered, one of the following fault details is displayed on the LCD.
- System
abnormalities
: FAIL SYSTEM
- Battery voltage
low
: FAIL BATTERY
- Calibration
abnormalities
: FAIL AIR CAL
- Clock
abnormalities
: FAIL CLOCK
- Low flow rate
: FAIL LOW FLOW
- Pump
abnormalities
: FAIL PUMP
- Sensor
abnormalities
: FAIL SENSOR
Alarm lamp
Repeatedly blinks at about one-second intervals.
Buzzer
Repeatedly sounds intermittent beeps at about
one-second intervals.
Blip-blip, blip-blip
LCD display
Display example of low flow rate (LOW FLOW)
If a fault alarm is triggered, refer to trouble shooting and take appropriate action.
If the unit has problems and is repeatedly malfunctioning, contact RKI immediately.
NOTE
The low flow rate alarm (FAIL LOW FLOW), calibration abnormalities (AIL AIR CL) and clock
abnormalities (FAIL CLOCK) can be reset by pressing the MODE button.
For information on malfunctions (error messages), see "Troubleshooting" on page 45.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKI Instruments SP-220 TYPE F and is the answer not in the manual?

RKI Instruments SP-220 TYPE F Specifications

General IconGeneral
BrandRKI Instruments
ModelSP-220 TYPE F
CategorySecurity Sensors
LanguageEnglish

Related product manuals