PressthePROGbuontoadvancetothenextstep.TheLCDwillshowthedigit1
withthehoursdigitashing.Usingthep or buttons, adjust the hours to the
meyouwishthenumber1eventtocommenceforthecurrentlyselectedday.
PressthePROGbuonagain,nowtheMinutesdigitsash.Usingthep or
buttons,settheminutetothemeyouwishthenumber1eventtobegin.
PressthePROGbuonagain,nowthewordHEAT(ifenabledbytheinstaller)
and a temperature value is shown in the LCD. Use the p or buttons to set the
desiredheangtemperaturetobemaintainedforthenumber1event.
Figure 6
PressthePROGbuonagain,nowthewordCOOL(ifenabledbytheinstaller)
and a temperature value is shown in the LCD. Use the p or buttons to set the
desired cooling temperature to be maintained for the number 1 event.
NOTE: The heating set temperature must be at least 2ºF (1ºC) lower than the
cooling set temperature. If you set the heating or cooling set temperature
closerthanthisminimumvalue,thethermostatwillautomaticallymove
the other setpoint away to maintain this minimum value.