12 Ethernet Network Appliance (with Network Address Translation)
Publication
9300-IN001A-EN-P - December 2012
Follow these steps to prepare the DC power cable.
1. Locate the power connector.
2. Identify the positive and return DC power connections on the
connector.
The positive DC power connection is labeled DC+ and the negative
DC power connection in the adjacent connection labeled DC-.
3. Measure a length of 0.82...0.52 mm
2
(18...20 AWG) copper wire long
enough to connect to the DC power source.
4. Using an 18-gauge wire-stripping tool, strip each of the two wires to
6.3 mm (0.25 in.) ±0.5 mm (0.02 in.).
Do not strip more than 6.8 mm (0.27 in.) of insulation from the wire.
Stripping more than the recommended amount of wire can leave
exposed wire from the connector after installation.
32322-M
GND
DC-
DC+
0.5 inch (12.7 mm)
31789-M