13 Parameter menu
PARAMETER
PARAMETER
VALUE
$ 
Selecting automation system model
WARNING! If this parameter is not set correctly, the automation system may not function properly.
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.

BG30/1600 - IRREVERSIBLE motor for gate leaves up to 1600 Kg.

BG30/2200 - IRREVERSIBLE motor for gate leaves up to 2200 Kg.

BG30/1000/HS - High Speed IRREVERSIBLE motor for gate leaves up to 1000 kg (see chapter 14 "Special
Parameters for High Speed Motor").

BG30/1400/R - REVERSIBLE motor for gate leaves up to 1400 kg (see chapter 15 "Special Parameters for
REVERSIBLE Motor").

BG30/1800/HS - High Speed IRREVERSIBLE motor for gate leaves up to 1800 kg (see chapter 14 "Special
Parameters for High Speed Motor").

BG30/1500/HS - High Speed IRREVERSIBLE motor for gate leaves up to 1500 kg (see chapter 14 "Special
Parameters for High Speed Motor").
$
Automatic closure after pause time (from gate completely open)

Disabled.

From 1 to 15 of gate closure attempts after photocell is triggered.
Once the number of attempts set is reached, the gate remains open.

9MJLFYJYWNJXYTHQTXJNSIJܪSNYJQ^
$ 
Automatic gate closing after mains power outage

Disabled. The gate does not close automatically when mains power is restored.

Enabled. If the gate is NOT completely open, when mains power is restored, the gate closes after a 5 second warning
XNLSFQQJI\NYMYMJܫFXMNSLQNLMYNSIJUJSIJSYQ^TKYMJ[FQZJXJY\NYMYMJUFWFRJYJW$). The gate closes in “position
recovery” mode (see chapter 20).
$ 
Selecting step mode control function (PP)

Open-stop-close-stop-open-stop-close...

Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents the
gate from closing when not required.
If automatic closing is disabled ($ ), the condominium function automatically attempts a closing manoeuvre $ .

Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents the
gate from closing when not required.
If automatic closing is disabled ($ ), the condominium function automatically attempts a closing manoeuvre $ .

Open-close-open-close.

Open-close-stop-open.
D 
5WJܫFXMNSL

)NXFGQJI9MJܫFXMNSLQNLMYNXFHYN[FYJIIZWNSLTUJSNSLFSIHQTXNSLRFSTJZ[WJX

Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.

XJHTSIܫFXMNSL\FWSNSLXNLSFQUWNTWYTHQTXNSLRFSTJZ[WJ

Other manuals for Roger Technology B70/1DCHP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roger Technology B70/1DCHP and is the answer not in the manual?

Roger Technology B70/1DCHP Specifications

General IconGeneral
BrandRoger Technology
ModelB70/1DCHP
CategoryControl Unit
LanguageEnglish

Related product manuals