PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
18
When [SS]=00 then the timer is disabled and flag operates in bi-stable mode (Latch Mode), setting [MM]=00 is
forbidden.
Default: <SS=00>
Note: The Flag Timers can be programmed in minutes or seconds. Controller always saves in its memory the
latest programmed value.
[73][SS] – Setting the LIGHT timer in seconds (SS=00-99) or
[73][*][MM] – Setting the LIGHT timer in minutes (MM=01-99)
The timer value can be defined in seconds (command [73][SS]) or in minutes (command [73][*][MM]).
When [SS]=00 then the timer is disabled and flag operates in bi-stable mode (Latch Mode), setting [MM]=00 is
forbidden.
Default: <SS=00>
[74][SS] – Setting the TAMPER timer in seconds (SS=01-99) or
[74][*][MM] – Setting the TAMPER timer in minutes (MM=01-99)
The timer value can be defined in seconds (command [74][SS]) or in minutes (command [74][*][MM]).
Setting [SS]=00 or [MM]=00 is forbidden.
Default: <MM=03>
[76][SS] – Setting the DURESS timer in seconds (SS=01-99) or
[76][*][MM] – Setting the DURESS timer in minutes (MM=01-99)
The timer value can be defined in seconds (command [76][SS]) or in minutes (command [76][*][MM]).
Setting [SS]=00 or [MM]=00 is forbidden.
Default: <MM=03>
[77][SS] – Setting the TROUBLE timer in seconds (SS=01-99) or
[77][*][MM] – Setting the TROUBLE timer in minutes (MM=01-99)
The timer value can be defined in seconds (command [77][SS]) or in minutes (command [77][*][MM]).
Setting [SS]=00 or [MM]=00 is forbidden.
Default: <MM=03>