Power Supply NGMO IEEE Commands
5-12 4.00 / 07-2004
Com-
mand
Parameter Par. value Description Def. SCPI
MAX On
DISPlay Sets LCD to
SAMPLE START
:PULSe [:MEAS-
ure]
:STARt? <CHAR_VAL> Queries pulse
measurement
status
Results:
OFF
ON
MIN OFF
DEFault OFF
MAX ON
:PULSe [:MEAS-
ure]
:TYPE <CHAR_VAL> Selects pulse
measurement and
read type
AVER
AGE
* AVERage Average
PEAK Peak
MIN Min
HIGH High
LOW Low
RMS Rms
DISPlay Sets LCD to
MEASURE +
READ TYPE
:PULSe [:MEAS-
ure]
:TYPE? <CHAR_VAL> Queries pulse
measurement and
read type
Results:
AVERAGE
PEAK
MIN
HIGH
LOW
RMS
:PULSe :TRIGger :LEVel :HIGH <CHAR_VAL> or
<NUM_VAL>
Sets trigger level
for 5A (HIGH)
range
2.5 A
1.00E-04 0.1 mA
7 7 A
AUTO or 0 Auto trigger
MIN 0 mA -> AUTO
* DEFault 2.5 A
MAX 7 A
DISPlay Sets LCD to
TRIGGER LEVEL
RANGE 5A
:PULSe :TRIGger :LEVel :HIGH? <CHAR_VAL> Queries trigger
level for 5A
(HIGH) range
Results: