IEEE Commands Power Supply NGMO
4.00 / 07-2004 5-13
Com-
mand
Parameter Par. value Description Def. SCPI
1E-4 <=
NUM_VAL <= 7
MIN 0.0
DEFault 2.5
MAX 5.0
:PULSe :TRIGger :LEVel :LOW <CHAR_VAL> or
<NUM_VAL>
Sets trigger level
for 0.5A (LOW)
range
2.5 mA
1.00E-05 0.01 mA
0.5 500 mA
AUTO or 0 Auto trigger
MIN 0A -> AUTO
* DEFault 250mA
MAX 500 mA
DISPlay Sets LCD to
TRIGGER LEVEL
RANGE 0.5 A
:PULSe :TRIGger :LEVel :LOW? <CHAR_VAL> Queries trigger
level for 5mA
range
Results:
1E-5 <=
NUM_VAL <= 0.5
MIN 0.0
DEFault 2.5E-1
MAX 5.0E-1
:PULSe :TRIGger :LEVel :DVM <CHAR_VAL> or
<NUM_VAL>
Sets trigger level
DVM
0 V
-5.999 -5.999 Volt
25.000 25.000 Volt
MIN AUTO
* DEFault 0 Volt
MAX 25.000 Volt
DISPlay Sets LCD to
TRIGGER LEVEL
DVM
AUTO Auto trigger
:PULSe :TRIGger :LEVel :DVM? <CHAR_VAL> Queries trigger
level DVM
Results:
-5.999 <=
NUM_VAL <=
25.000
MIN AUTO
DEFault 0.000
MAX 25.000
:PULSe :TRIGger :SOURce <CHAR_VAL> Selects trigger
source
INT
INT Intern