EasyManua.ls Logo

Rohde & Schwarz NGMO1 - Page 70

Rohde & Schwarz NGMO1
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Supply NGMO IEEE Commands
5-18 4.00 / 07-2004
Com-
mand
Parameter Par. value Description Def. SCPI
MIN 0
DEFault 15
MAX 15
:VOLTage [:LEVel] [:IMMedi-
ate]
[:AMPLi-
tude]
<CHAR_VAL> or
<NUM_VAL>
Sets voltage amp-
litude in 1 mV
steps
0
0.000 0 Volt
15.000 15 Volt
MIN 0 Volt
* DEFault 0 Volt
MAX 15 Volt
DISPlay Sets LCD to main
display
:VOLTage [:LEVel] [:IMMedi-
ate]
[:AMPLi-
tude]?
<CHAR_VAL> Queries voltage
amplitude
Results:
0.000 <=
NUM_VAL <=
15.000
MIN 0
DEFault 0
MAX 15
:CURRent [:LIMit] [:VALue] <CHAR_VAL> or
<NUM_VAL>
Sets current limit
in Amps (max.
2.5A on voltages
above 5V)
2
0.000 0.000A
5.000 5.000A
MIN 0.000A
* DEFault 2.000A
MAX 5.000A
DISPlay Sets LCD to main
display
:CURRent [:LIMit] [:VALue]? <CHAR_VAL> Queries current
limit
Results:
0.000 <=
NUM_VAL <=
5.000
MIN 0
DEFault 5
MAX 5
:CURRent [:LIMit] :MAXSet-
ting
<CHAR_VAL> or
<NUM_VAL>
Sets maximum
settable current
limit
5
0.000 0.000A
5.000 5.000A
MIN 0.000A
* DEFault 5.000A
MAX 5.000A

Other manuals for Rohde & Schwarz NGMO1