IEEE Commands Power Supply NGMO
4.00 / 07-2004 5-19
Com-
mand
Parameter Par. value Description Def. SCPI
DISPlay Sets LCD to:
Maximum output
current
:CURRent [:LIMit] :MAXSet-
ing?
<CHAR_VAL> Queries max.
settable current
limit
Results:
0.000
<= NUM_VAL
<= 5.000
MIN 0
DEFault 5
MAX 5
:CURRent [:LIMit] :TYPE <CHAR_VAL> Sets current limit
type
LIMIT
LIMit Limit
TRIP Trip
MIN Limit
* DEFault Limit
MAX trip
DISPlay Sets LCD to:
Main display
:CURRent [:LIMit] :TYPE? <CHAR_VAL> Queries current
limit type
Results:
LIMIT
TRIP
MIN LIMIT
DEFault LIMIT
MAX TRIP
:CURRent [:LIMit] :STATe? Queries current
limit state
Results:
1 -> in current limit
or output tripped
0 -> not in LIMIT /
TRIP