Power Supply NGMO IEEE Commands
5-24 4.00 / 07-2004
Com-
mand
Parameter Par. value Description Def. SCPI
:SYSTem :CLEar Clears the error
queue
:SYSTem :COMM-
unicate
:SERial :ENABle <CHAR_VAL> Enables or
disables the serial
interface
OFF
OFF Disable
ON Enable
MIN Disable
* DEFault Disable
MAX Enable
DISPlay Sets LCD to:
Serial Interface
ON/OFF
:SYSTem :COMM-
unicate
:SERial :ENABle? <CHAR_VAL> Queries serial
interface enable
ON/OFF state
Results:
OFF
ON
MIN OFF
DEFault OFF
MAX ON
:SYSTem :COMM-
unicate
:SERial :BAUD <CHAR_VAL> or
<NUM_VAL>
Sets serial baud
rate
9600
300 300 baud
600 600 baud
1.200 1200 baud
2.400 2400 baud
4.800 4800 baud
9.600 9600 baud
19.200 19200 baud
38.400 38400 baud
MIN 300 baud
* DEFault 9600 baud
MAX 38400 baud
DISPlay Sets LCD to:
Serial speed
:SYSTem :COMM-
unicate
:SERial :BAUD? <CHAR_VAL> Queries serial
baud rate
Results:
300
600
1200
2400
4800
9600
19200